Service difficulty report · Relay · Emb ERJ170100SE

Difficulty date
December 2, 2011
Submitted
December 7, 2011
Operation
Air carrier
Aircraft
N647RW
Make and model
Emb ERJ170100SE
Aircraft serial
17000067
Aircraft time
19,651 hours, 12,151 cycles
Part
Relay
Condition
Failed
Location
E&E Bay
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

"CTR EBAY FANS FAIL" IN FLIGHT. RAN QRH, DECLARED EMERGENCY, LANDING UNEVENTFUL. CLEANED TRUS, RESET POWER, MESSAGE RETURNED. FERRIED TO IND. REMOVED AND REPLACED K5 RELAY IN LICC FOR MID EBAY FAN 1 IAW SWPM 20-32-02. OPS CHECK GOOD IAW AMM 21-26-00. PER MOC REQUEST ALSO REPLACED K9 AND K10 RELAYS IN EICC AND EMERGENCY FAN IN MID EBAY. MESSAGE RETURNED THE NEXT DAY ON POWER UP AND THE MID EBAY FLOW SENSOR WAS REPLACED.

More about the Emb ERJ 170-100 SE