What was found
MAJOR REPAIR - BIRD STRIKE DENT RT NOSE BETWEEN FR4-5 AND BELOW STR 10R AND STR 9R 9.5"X5.25"X0.3125" WITH CREASE ON FCS WITH OIL CANNING. REPAIRED DAMAGE PER ETD 2011-170-108532 REV D, STRIPPED PAINT IAW EMB 170 SRM 51-23-02, CUTOUT DAMAGED AREA PER ETD, INSPECTED AND PERFORMED HFEC TO RT SIDE CUTOUT, NO CRACK LIKE INDICATIONS NOTED, FABRICATED REPAIR DOUBLER AND FILLER, BACK DRILLED EXISTING HOLES AND DEVELOPED FIELD RIVET PATTERN AND DRILLED ONTO DOUBLER/FILLER.