What was found
LEVEL 2 CORROSION AFT WET AREA RT BEAM, CORRODED 6 INCHES AFT OF FRAM 86. REMOVED AND REPLACED BEAM IAW EMB 170 SRM 51-43-01 AND 51-41-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION AFT WET AREA RT BEAM, CORRODED 6 INCHES AFT OF FRAM 86. REMOVED AND REPLACED BEAM IAW EMB 170 SRM 51-43-01 AND 51-41-01.