What was found
MAJOR REPAIR - FOUR DENTS BETWEEN FR9-11 JUST ABOVE STR 17L. REMOVED PAINT FROM AREA IAW EMB 170 SRM 51-23-02, RECONTOURED SKIN AT FR10L, FOUND SKIN OIL CANNING. CUT AND REMOVED DAMAGED AREA IAW EMB 170 SRM 53-10-01 ABD 51-75-12. PERFORMED HFEC, NO CRACKLIKE INDICATIONS NOTED IAW EMB 170 NDT MANUAL. FABRICATED DOUBLER AND FILLER AND INSTALLED IAW EMB 170 SRM 51-41-02, EDGE SEALED AND PAINTED, AND PERFORMED HFEC AGAIN IAW EMB 170 NDT MANUAL, NO CRACKLIKE DAMAGE NOTED.