What was found
L1 DOOR ARMING HANDLE NOT CLOSING CORRECTLY. ALL INDICATIONS CORRECT, HANDLE MISALIGNED. RE-SECURED GIRT BAR INTO CLAMP AND PERFORMED OPS CHECK IAW AMM 52-12-40.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L1 DOOR ARMING HANDLE NOT CLOSING CORRECTLY. ALL INDICATIONS CORRECT, HANDLE MISALIGNED. RE-SECURED GIRT BAR INTO CLAMP AND PERFORMED OPS CHECK IAW AMM 52-12-40.