Service difficulty report · Sensor · Emb ERJ170100SE

Difficulty date
August 15, 2013
Submitted
August 26, 2013
Operation
Air carrier
Aircraft
N639RW
Make and model
Emb ERJ170100SE
Aircraft serial
17000057
Part
Sensor
Condition
Malfunctioned
Location
Bleed Pressure
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

BLEED 1 OVER PRESSURE ON CLIMB, BLEED 1 AT 75PSI. RAN QRH, MESSAGE REMAINED. RETURNED TO DEPARTURE, DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R & R BLEED 1 NAPRSOV IAW AMM 36-11-03 AND BLEED PRESSURE SENSOR IAW AMM 36-14-02.

More about the Emb ERJ 170-100 SE