Service difficulty report · Control Column · Emb ERJ170100SE

Difficulty date
January 3, 2014
Submitted
January 7, 2014
Operation
Air carrier
Aircraft
N652RW
Make and model
Emb ERJ170100SE
Aircraft serial
17000075
Aircraft time
25,168 hours, 15,581 cycles
Part
Control Column
Condition
Damaged
Location
Zone 100
Stage of operation
CL
How discovered
O
Nature of condition
E, J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PITCH CONTROL DISCONNECTED AROUND 2,000 FT ON TAKEOFF, BOTH CONTROLS SEPARATED, AOA LIMIT EICAS MESSAGE ASSOCIATED WITH DISCONNECT. R & R CONTROL COLUMN DISCONNECT DEVICE IAW AMM 27-31-06. PERFORMED OPS CHECK IAW AMM 27-31-00-710-801-A/500, OPS CHECK GOOD.

More about the Emb ERJ 170-100 SE