What was found
DURING INSPECTION, THE CENTER OMEGA BEAM WAS FOUND TO BE CORRODED FROM FRAME 19 TO FRAME 22. THE BEAM WAS REPLACED IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, THE CENTER OMEGA BEAM WAS FOUND TO BE CORRODED FROM FRAME 19 TO FRAME 22. THE BEAM WAS REPLACED IAW SRM 51-40-02.