What was found
DURING INSPECTION, A DENT WAS FOUND ON FRAME 62 AT STRINGER 16R. A REPAIR DOUBLER WAS INSTALLED IAW SRM 53-00-04.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, A DENT WAS FOUND ON FRAME 62 AT STRINGER 16R. A REPAIR DOUBLER WAS INSTALLED IAW SRM 53-00-04.