What was found
DURING INSPECTION, THE CENTER OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 20. THE BEAM WAS REPLACED IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, THE CENTER OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 20. THE BEAM WAS REPLACED IAW SRM 51-40-02.