What was found
AVNX MAU 2B FAIL ON EICAS. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. TROUBLESHOT IAW FIM 45-45-00-810-942-A. R & R MAU 2 NIC 2 IAW AMM 31-41-04 WITH PRE-LOADED NIC PROCESSOR MODULE, MESSAGE NO LONGER PRESENT ON THE EICAS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AVNX MAU 2B FAIL ON EICAS. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. TROUBLESHOT IAW FIM 45-45-00-810-942-A. R & R MAU 2 NIC 2 IAW AMM 31-41-04 WITH PRE-LOADED NIC PROCESSOR MODULE, MESSAGE NO LONGER PRESENT ON THE EICAS.