Service difficulty report · Sensor · Emb ERJ170200LR

Difficulty date
September 13, 2015
Submitted
September 16, 2015
Operation
Air carrier
Aircraft
N216JQ
Make and model
Emb ERJ170200LR
Aircraft serial
17000273
Aircraft time
14,836 hours, 10,950 cycles
Part
Sensor
Condition
Malfunctioned
Location
Te Flaps
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLAP FAIL EICAS MESSAGE DURING CLIMB THROUGH FL300. FLAPS INDICATED 0, SLATS INDICATED 0. DECLARED EMERGENCY, DIVERTED, LANDED WITHOUT INCIDENT. LANDED WITH SLAT 3, FLAPS 0 AT APPROXIMATELY 178KTS. R & R RT NR 2 FLAP ACTUATOR IAW MM 27-51-01. R & R RT T3 AND T4 SKEW SENSORS IAW MM 27-53-06. OPS CHECKED SATISFACTORY.