Service difficulty report · Duct · Emb ERJ170100SE

Difficulty date
March 7, 2016
Submitted
March 11, 2016
Operation
Air carrier
Aircraft
N634RW
Make and model
Emb ERJ170100SE
Aircraft serial
17000055
Aircraft time
31,889 hours, 19,819 cycles
Part
Duct
Condition
Detached
Location
Gasper Valve
Stage of operation
CR
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

EMERGENCY DIVERSION, SMOKE ODOR IN AFT CABIN. DECLARED EMERGENCY, DIVERTED, LANDED WITHOUT INCIDENT. FOUND GASPER VALVE DUCT BLOWN OFF. REINSTALLED IAW AMM 21-24-03. R & R RECIRCULATING FILTERS IAW AMM 21-24-02. INSPECTED ALL 3 AVIONICS BAYS WITH BURNING ODOR, PERFORMED OPS CHECK OF APU AND ENGINE BLEEDS IAW AMM 36-00-00. OK FOR SERVICE.