What was found
CF1 FLOOR STRUCTURE FWD AND AFT SERVICE DOOR SILL CORRODED. CF1 FLOOR STRUCTURE FWD DOOR SILL REPAIRED IAW SRM 53-21-10. CF1 FLOOR STRUCTURE AFT SILL OF SERVICE DOOR REPAIRED IAW SRM 53-21-10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CF1 FLOOR STRUCTURE FWD AND AFT SERVICE DOOR SILL CORRODED. CF1 FLOOR STRUCTURE FWD DOOR SILL REPAIRED IAW SRM 53-21-10. CF1 FLOOR STRUCTURE AFT SILL OF SERVICE DOOR REPAIRED IAW SRM 53-21-10.