Service difficulty report · Pump · Emb ERJ170100SE

Difficulty date
July 8, 2016
Submitted
July 12, 2016
Operation
Air carrier
Aircraft
N869RW
Make and model
Emb ERJ170100SE
Aircraft serial
17000133
Aircraft time
23,071 hours, 17,209 cycles
Part
Pump
Condition
Failed
Location
Hyd System
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

TOTAL LOSS OF HYDRAULIC SYSTEM 2 IN FLIGHT (TOTAL LOSS). RAN QRH. FREE FALLED THE GEAR. DECLARED EMERGENCY, DIVERTED, LANDED WITHOUT INCIDENT. R & R NR 2 HYDRAULIC PUMP PRESSURE UNION AND REPAIRED LINE AT RT WING AFT SPAR AFT OF PYLON AREA IAW AMM 20-10-03. LEAK CHECK GOOD.