What was found
DURING CURRENT (D) CHECK, SIAEC, FOUND STA 440L FRAME CRACKED AT CUTOUT OF STR 10A. CRACK LENGTH .1875. STOP DRILLED CRACK, FABRICATED REPAIR DOUBLER AND INSTALLED PER SRM. FRAME IS SUBJECT TO RECURRENT INSPECTIONS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CURRENT (D) CHECK, SIAEC, FOUND STA 440L FRAME CRACKED AT CUTOUT OF STR 10A. CRACK LENGTH .1875. STOP DRILLED CRACK, FABRICATED REPAIR DOUBLER AND INSTALLED PER SRM. FRAME IS SUBJECT TO RECURRENT INSPECTIONS.