Service difficulty report · Wire · Boeing 74747UF

Difficulty date
June 7, 2008
Submitted
July 28, 2008
Operation
Air carrier
Aircraft
N499MC
Make and model
Boeing 74747UF
Aircraft serial
29260
Part
Wire
Condition
Chafed
Location
Hyd Pump
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CRUISE, EICAS ADVISORY "HYD PRESS ENGINE 1" ON HYD SYNOPTIC. NR EDP AND DEMAND PUMPS RUNNING. THEN NOTED EDP INTERMITTENT AND IAW CHECKLIST EDP SWITCH OFF, BUT PUMP DID NOT SWITCH OFF. (EDP CONTINUED RUNNING INTERMITTENTLY AND DEMAND PUMP RUNNING). LATER NOTICED THAT "EDP PRESS 1 CIRCUIT BREAKER WAS POPPED. ATTEMPTED RESET BUT C/B POPPED AGAIN. AFTER CONSULTING WITH MCC AND DISPATCH, DIVERTED. FOUND AND REPAIRED CHAFED WIRING AT EDP, DEPRESSURIZATION SOLENOID CONNECTOR IAW WDM 29-11-01. NR 1 SYSTEM DEPRESSURIZATION SOLENOID CIRCUIT BREAKER RESET AND OPERATIONS CHECKED OKAY IAW 29-17-00. (K)