What was found
FOUND STATION 1480 STRINGER 39R FOUND TWO HOLES INSTALLED IN THE RADIUS. REMOVED CORNER FITTING, REDRILLED AND SLEEVED HOLES, REINSTALLED FITTING. INSTALLED FASTENERS PER SB 747-53A2390. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND STATION 1480 STRINGER 39R FOUND TWO HOLES INSTALLED IN THE RADIUS. REMOVED CORNER FITTING, REDRILLED AND SLEEVED HOLES, REINSTALLED FITTING. INSTALLED FASTENERS PER SB 747-53A2390. (M)