What was found
WHILE INSPECTION FRAME STATION 1265 BELOW FORWARD END OF MAIN ENTRY DOOR NR 3 CUT OUT AT WL 199, EDDY CURRENT CHECK INDICATED CRACK INDICATIONS L/S HOLE NR 10 AND R/S AT THE 10 O'CLOCK POS. HOLES REWORKED AND CRACKS STOP HOLED AS REQUIRED. REPAIR ANGLES, DOUBLERS AND NEW INTERCOSTAL INSTALLED PER SB747-A2416 BOTH LEFT AND RIGHT SIDES. REPAIR TO BE RE-INSPECTED AT 2000 FLIGHTS. (M)