What was found
RIGHT STATION 1480 BULKHEAD CORROSION REPAIR COMMON TO STRINGER 38R. FOUND HOLES NR 2, 3, 5, 7, AND NR 10 CRACKED. REAMED HOLES OVERSIZE, ALL WITHIN LIMITS PER SB 747-53A2390. OVERSIZED FASTENERS INSTALLED. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT STATION 1480 BULKHEAD CORROSION REPAIR COMMON TO STRINGER 38R. FOUND HOLES NR 2, 3, 5, 7, AND NR 10 CRACKED. REAMED HOLES OVERSIZE, ALL WITHIN LIMITS PER SB 747-53A2390. OVERSIZED FASTENERS INSTALLED. (M)