What was found
DURING ROUTINE INSPECTION, FOUND FRAME DENTED AT STATION 1760 STRINGER 13R. TRIMMED AWAY DAMAGE. FABRICATED REPAIR DOUBLERS, FILLERS AND SHEAR TIE. INSTALLED PER STANDARD PRACTICES. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE INSPECTION, FOUND FRAME DENTED AT STATION 1760 STRINGER 13R. TRIMMED AWAY DAMAGE. FABRICATED REPAIR DOUBLERS, FILLERS AND SHEAR TIE. INSTALLED PER STANDARD PRACTICES. (M)