What was found
DURING HFEC INSPECTION, FOUND UPPER FORWARD CORNER OF AFT LOWER LOBE CARGO COMPT CRACKED .87 INCHES AT BS 1815, STRINGER 27R. TRIMMED OUT CRACKED AREA. FABRICATED FILLER AND REPAIR STACK UP DOUBLERS PER SRM 53-30-03 FIG 60, TYPE II. INSTALLED PER SRM REPAIR SCHEME AS NOTED ABOVE. (M)