As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSPECTION, FOUND FRAME CRACKED STATION 800 STRINGER 17L ADJACENT TO 2L MED. STOP DRILL NOT REQUIRED DUE CRACK RAN OFF END OF FRAME. FABRICATED REPAIR STACK UP DOUBLERS. INSTALLED PER STANDARD SRM PRACTICES. REF SB 53-10-04 FIG 114. (M)