What was found
DURING HFEC INSPECTION, FOUND FRAME STATION 800 CRACKED AT STRINGER 17R COMMON TO THE AFT INNER CHORD AT A FASTENER HOLE. TRIMMED OUT CRACK. FABRICATED FILLER AND REPAIR STRAPS AND INSTALLED PER STANDARD PRACTICES IAW SRM 53-10-04 FIG 114. HFEC (FLAT SURFACE) REINSPECTION TO BE ACCOMPLISHED OF THE ENTIRE STACK UP AND SURROUNDING AREA AT 3000 CYCLE INTERVALS. (M)