As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSPECTION, FOUND MAIN DECK FLOOR LINE INTERCOSTALS FROM STATION 340-380 LEFT CRACKED AT NUMEROUS FASTENER HOLES. TRIMMED OFF SHEAR TIES CONTAINING CRACKED FASTENER HOLES. PERFORMED HFEC INSPECTION AT CUT LINE TO ENSURE NO CRACKS. NO CRACKS FOUND. FABRICATED REPAIR ANGLES, INSTALLED PER STANDARD SRM PRACTICES. (M)