What was found
DURING INSPECTION FOUND SHIMS MIGRATING FROM BS 1240 LEFT/RIGHT BULKHEAD UPPER CHORD FITTING. REMOVED BOLTS IN AFFECTED AREA, TRIMMED SECTION OF MIGRATED SHIM. FABRICATED REPLACEMENT SHIM FROM SOLID MATERIAL, ALODINED AND PRIME PAINTED. REINSTALLED REMOVED BOLTS. AREA TO BE REINSPECTED EVERY C-CHECK UNTIL ENTRIRE SHIM IS REPLACED. (M)