As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING HFEC INSPECTION PER AD 96-26-04 REFERENCES SB 747-53A2293 FOUND FRAME STATION 320 RIGHT CRACKED AT AN INSULATION BLANKET STUD MOUNTING HOLE. REMOVED FRAME. REPLACED FRAME WITH P/N 65B07942-564 PER SB 747-53A2293 IAW SRM 51-30-02. (M)