What was found
DURING CURRENT C-CHECK AT SIAEC, FOUND KEEL BEAM BOX, LOWER CHORD, INNER VERTICAL SURFACE CORRODED LEVEL 1, AT BS 1267 RBL 10. CORROSION REMOVED BY BLENDING. HFEC INSPECTED AREA FOR ADDITIONAL CORROSION. NO CORROSION FOUND. ORIGINAL THICKNESS BEFORE BLENDING WAS .300, AFTER BLENDING .220 REMAINING. (M)