What was found
D-CHECK, DURING MAINTENANCE INSPECTION, ELONGATION DAMAGE WAS FOUND AT OB TRAILING EDGE FLAP TRACK NR 8 MOVABLE FAIRING ASSEMBLY HINGE FITTING LUGS. OVERSIZED THE BORES. DYE PENETRANT THE BORES TO ENSURE DEFECT FREE CONDITION. REFINISHED, INSTALLED ONE PIECE REPAIR SLEEVE AND A NEW DESIGN TYPE BEARING.