What was found
STA 1980-2000, STR 42-44, RT (2 EA) DENT (A) AND (B) WERE FOUND ON THE EXT FUSELAGE. DENT (A) STA 1980-2000, STR 42-43, RT D=0.09, W=1.15 INCH, L=3.8 INCH. DENT (B) STAT 1980-2000, STR 43-44, RT D=0.051, W=1.18, L=1.54. THE DAMAGED AREA TRIMMED OUT. A REPAIR PATCH WAS INSTALLED IAW SRM. THE REPAIR DOUBLER WAS INSTALLED WITH FASTENERS IAW SRM. PERFORMED HFEC INSPECTION AROUND CUTOUT AREA, NO CRACKS WERE FOUND. (K)