What was found
STA 2660-2680, 2 DENTS FOUND ON EXT SKIN. REPORTED DENT WAS REPAIRED IAW SRM. PERFORMED HFEC INSP, NO CRACKS WERE FOUND. AFTER SECONDARY INSP FOUND DENT, CREASE, AND CHAFING 2.5 INCH X 1.5 INCH X 0.050 INCH. DOUBLER REPAIR PERFORMED IAW SRM. (K)