What was found
FOUND UPPER DECK FLOORBEAM ONE STIFFENER CRACKED AT BS 400 LBL15. UPPER DECK FLOORBEAM STIFFENER REPLACED AS PER SRM 51-10-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND UPPER DECK FLOORBEAM ONE STIFFENER CRACKED AT BS 400 LBL15. UPPER DECK FLOORBEAM STIFFENER REPLACED AS PER SRM 51-10-01.