What was found
RT BS 900 TENSION TIE AREA NR 5 HOLE FOUND CRACK AT FRAME WEB THRU THICKNESS RUNNING I/B AND NR 10 HOLE FOUND CRACK AT FRAME WEB APPROX 0.060" IN LENGTH RUNNING DOWNWARD. CRACKED FRAME WEB REPAIRED AS PER BOEING MSG 1-306586780-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT BS 900 TENSION TIE AREA NR 5 HOLE FOUND CRACK AT FRAME WEB THRU THICKNESS RUNNING I/B AND NR 10 HOLE FOUND CRACK AT FRAME WEB APPROX 0.060" IN LENGTH RUNNING DOWNWARD. CRACKED FRAME WEB REPAIRED AS PER BOEING MSG 1-306586780-2.