What was found
AFT CARGO COMPARTMENT STA 1700 RBL 55 FLOORBEAM CHORD ANCHOR NUT AREA FOUND MINOR CORROSION. LEVEL 1, BLENDED OUT CORROSION IAW SRM 51-10-01 0.049" 1" WIDE 2" LONG. REPROTECTED PER 51-10-02. APPLIED CORROSION INHIBITOR COMPOUND.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO COMPARTMENT STA 1700 RBL 55 FLOORBEAM CHORD ANCHOR NUT AREA FOUND MINOR CORROSION. LEVEL 1, BLENDED OUT CORROSION IAW SRM 51-10-01 0.049" 1" WIDE 2" LONG. REPROTECTED PER 51-10-02. APPLIED CORROSION INHIBITOR COMPOUND.