As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO DOOR FAILED TO CLOSE DURING NORMAL OPERATION. FOUND AFT POSITION ROTARY LIFT ACTUATOR FRAME REINFORCEMENT FITTING CRACKED. REPLACED FITTING 65B38174-3 PER STANDARD PRACTICES IAW SRM 51-30-02 AND LIFT ACTUATOR 60B00305-1 PER AMM 52-34-03. OPS CHECK NORMAL.