As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MULTIPLE BLEED OVHT EICAS MESSAGES, COMPLETED QRH PROCEDURES, SMELLED BURNING ODOR. CLOSED LT BLEED SHUTOFF VALVE. STATUS MESSAGE BLEED PRV ENG 2. PERFORMED ENGINE RUN WITH BLEED OFF AND ON. NO BURNING ODOR PRESENT. DISPATCHED THE ACFT WITH HIGH STAGE BLEED LOCKED OUT AND THE THRUST REVERSER STOWED AND DEACTIVATED IAW THE MEL.