What was found
PART 1-4 FOUND DAMAGE WEAR ON LT AND RT SIDE VERTICAL STAB SEAL INTERFACE SKIN AREA BETWEEN BS 2360-2390 AND BS 2521-2598 AND BS 2280- 2360. BLEND OUT DAMAGE AREA IAW SRM 53-00-01 REV 53 RESIDUAL MATERIAL THICKNESS WITHIN ALLOWABLE DAMAGE, APPLY PROTECTIVE COATING AND PRIMER, CONDITION CHECK NORMAL AND JOB COMPLETED.