What was found
CRACK ON UPPER DECK FLOORBEAM WEB BS 460 RBL 33-55. ACCOMPLISHED PER REA: MF00656R0008 AND RFTA: 00656-0008. CRACKED AREA TRIMMED OUT REINFORCE WITH EXTRUDED TEE AND SPLICE AND FILLERS (2EA) P/N N517MC-NRC178-1/2/3/4 PER SRM 53-10-07 FIG 11 USING FASTENER PER SRM 51-30-02. INITIAL DVI AT 6000 FC, REPEAT THEREAFTER AT 3000 FC PER EO NR 4753B238.