What was found
DURING C-CHECK, DAMAGE WAS FOUND IN THE 65B04141-2 SKIN AT BS 1940, S-40L TO -41L.THE DAMAGE WAS TRIMMED OUT AND REPAIRED IAW NRC 270 AND SRM 53-30-03, FIGURE 18 (SEE FIGURES 1 AND 2). THE 65B04141-2 SKIN IS MADE FROM 0.063 INCH THICK 2024-T3 CLAD ALUMINUM SHEET IAW QQ-A-250/5. THE REPAIR CONSISTS OF AN 0.071 INCH THICK DOUBLER THAT MEASURES 12.0 INCH BY 12.0 INCH AND AN 0.071 INCH THICK STRUCTURAL FILLER THAT MEASURES 14.0 INCH BY 10.0 INCH.