What was found
THE PURPOSE OF THIS EO IS TO DOCUMENT THE PERMANENT REMOVAL OF CRACK DAMAGE FROM AREAS OF 65B06165-49 INTERCOSTAL. REPAIR OF CRACK DAMAGE AT BS 2000 ON INTERCOSTAL AT BL 0 AS DOCUMENTED IAW EGAT NCR 609 WAS REPAIRED IAW EGAT EI T2010A53B-1876. THE DAMAGED INTERCOSTAL WAS R & R. THE REPLACEMENT 65B06165-49 INTERCOSTAL WAS MFG IAW DWG 65B06165 AS AUTHORIZED IAW SMAL PO225642. REPLACEMENT 65B06165-49 INTERCOSTAL WAS ATTACHED IAW STRUCTURE INSTALLATION DWG 146U5090. EGAT EI T2010A53B-1876 (SEE FIG 3) FABRICATION AND INSTALLATION OF A REPLACEMENT 65B06165-49 INTERCOSTAL WAS APPROVED.