What was found
DURING WALK AROUND INSP BEING PERFORMED, MX FOUND THE- LEADING EDGE PANEL - LOWER SURFACE EXTERNAL SKIN WITH DELAMINATION DAMAGE (AREA: MEASURES 33.0 IN. X 36 IN.) (REF FIGURE 1).(EO4757A497 DISPOSITION WAS MADE TO PERFORM A TIME LIMITED REPAIR AS DESCRIBED IN PART 1 WORK INSTRUCTIONS IAW THE SRM 51-40-16 FIG 1, REPEAT DETAIL VISUAL INSP AT EVERY 1,000 FH (FLIGHT HOURS) AND PERMANENT REPAIR IAW THE SRM 51-40-09 FIG 18 IAW 51-40-12 AT THE NEXT C CHECK AFTER PART 1.)