What was found
DURING C-CHECK, AN INTERCOSTAL LOCATED COMMON TO THE BULK CARGO FLOOR HAD DAMAGE THAT IS LISTED AS FOLLOWS: THE INTERCOSTAL AT BS1980, RBL30 WAS CRACKED SEE FIGURE 1, SHEET 2, ITEM 18 AS DOCUMENTED ON NRC518. (THE INTERCOSTAL AT BL30 IS MADE FROM BAC1517-1671, 7075-T6 EXTRUSION IAW SRM 53-10-23, FIG 5, SHEET 11, ITEM 18, FIG 1. THE REPAIR PARTS WERE AN ANGLE AND FILLER MADE FROM 0.040 7075-T6 AND INSTALLED WITH BACB30MY6K HI-LOKS AS DOCUMENTED ON NRC518. FIG 2. THE SUBJECT REPAIR IS PERMANENT AND DOES NOT AFFECT THE REPAIR ASSESSMENT PROGRAM IAW FAR 121.1109, THEREFORE NO SUPPLEMENTAL INSPECTIONS ARE REQUIRED.)