What was found
DURING WALK AROUND INSP AT MX, REPORTED RT NR 14 L/E KRUEGER FLAP EXTERNAL SKIN (EDGEBAND) - DELAMINATION MEASURING 0.4 INCH WIDTH AND 10 PERCENT OF EDGEBAND LENGTH (REF FIG 1). DISPOSITION WAS MADE TO PERFORM TIME LIMITED REPAIR IAW SRM 51-70-02-1A FIG 101 SHEETS 3 AND 10; SCHEDULE REPEAT INSP AT EVERY 1,000 FH (FLIGHT HOURS) IAW PART 2 AND PERMANENT REPAIR IAW PART 3 AT THE NEXT C CHECK AFTER PART 1 IAW THE SRM 57-43-02, FIG 201, REPAIR 1, TABLE IV (SH 8 OF 9) IAW SRM 51-70-07 (250° FCURE).