What was found
DURING WALKAROUND INSP, MX REPORTED DELAMINATION DAMAGE FOUND ON THE RT OTBD MID FLAP - WBL565 L/E PANEL. THE DAMAGE IS LOCATED INBD OF FLAP TRACK, NR 7 MEASURING 24 IN X 16 IN (REF FIG 1). THE DAMAGED AREA EXCEEDS THE SRM 57-53-01, FIG 101, ALLOWABLE DAMAGE 1 LIMITS. DISPOSITION WAS MADE TO PERFORM TIME LIMITED REPAIRS AS DESCRIBED IN PART 1 WORK INSTRUCTIONS; SCHEDULE REPEAT / INSPECTIONS AT EVERY 25FC IAW PART 2 AND PERMANENT REPAIR IAW PART 3 PRIOR TO THE ACCUMULATION OF 4,000 FLIGHT HOURS AFTER PART 1.