What was found
DURING WALKAROUND INSP, MX REPORTED DENT DAMAGE FOUND ON THE LT OTBD FORE FLAP - WBL745 UPPER EXTERNAL SKIN PANEL. MEASURING 5.0 IN LENGTH X 3.125 IN. WIDTH & AMP; 0.625 IN. (REF FIG 1). THE DAMAGED AREA EXCEEDS THE SRM 57-53-01, FIG 101, ALLOWABLE DAMAGE 1 LIMITS. (DISPOSITION WAS MADE TO PERFORM TIME LIMITED REPAIR AS DESCRIBED IN PART 1 WORK INSTRUCTIONS; SCHEDULE REPEAT INSPECTIONS AT EVERY 25FC IAW PART 2 AND PERMANENT REPAIR IAW PART 3 PRIOR TO THE ACCUMULATION OF 4,000 FLIGHT HOURS AFTER PART 1.)