What was found
DURING THE D02 PLUS C03, GENERAL DAMAGE WAS DETECTED ON STIFFENER, DEFORMED DAMAGE WAS DETECTED ON 65B04925-47 STIFFENER, AND IMPACT CRACK DAMAGE WAS DETECTED ON THE 65B04925-84 STIFFENERS (2 PLACES).( REPAIR OF GENERAL DAMAGE ON 65B04325-42 STIFFENER AT BS 1760/S-43R-44R, AS DOCUMENTED IAW EGAT NCR 694 WAS REPAIRED IAW EGAT EI T2011P53B-176. THE DAMAGED STIFFENER WAS REMOVED AND REPLACED. REPAIR OF DEFORMED DAMAGE ON 65B04925-47 STIFFENER AT BS 1640/S-47-49R, AS DOCUMENTED IAW EGAT NCR 693 WAS REPAIRED IAW EGAT EI T2011P57B-142. THE DAMAGED STIFFENER WAS R & R. REPAIR OF CRACK IMPACT DAMAGE ON 65B04925-84 STIFFENER AT BS 1640/S-49R AND BS 1720/S-49R, AS DOCUMENTED IAW EGAT NCR 692/693 WERE REPAIRED IAW EGAT EI T2011P53B-177. THE DAMAGED STIFFENERS (2 PLACES) WERE R & R.