What was found
DURING D-CHECK INSP OF DATUM ACFT, DAMAGE (WORN HOLE) WAS FOUND ON SUPPORT FITTING OF APU LT SUPPORT LINK FWD SIDE AT STA 2658 (REFER TO FIG 1 FOR DAMAGE LOCATION). (THE REPAIR (FIG 2) WAS PERFORMED IAW EGA-TLS-11-0009 AND WAS APPROVED IAW SR 1-1777633064 AND RDR DATED JAN. 21, 2011 (FIG 3). NOTE: THE REPAIR BUSHING WAS FABRICATED DIRECTLY FROM 1.0 IN DIA 17-4PH H925 (180-200 KSI, HRC 40-43) CONDITION IAW AMS 5643.)