What was found
HYDRAULIC SYS NR 4 ADP CONT CIRCUIT BREAKER OPENS WHEN CONTINUOUS SELECTED. RUN LT ILLUMINATES MOMENTARILY. WIRING CHECKED IAW 29-34-12 FOUND WIRES SHORTED TO GROUND. WIRING REPAIRED IAW SWPM 20-10-13.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HYDRAULIC SYS NR 4 ADP CONT CIRCUIT BREAKER OPENS WHEN CONTINUOUS SELECTED. RUN LT ILLUMINATES MOMENTARILY. WIRING CHECKED IAW 29-34-12 FOUND WIRES SHORTED TO GROUND. WIRING REPAIRED IAW SWPM 20-10-13.