What was found
DURING WALK-AROUND INSP, MX REPORTED DAMAGE WAS FOUND TO THE RT FUSELAGE SKIN BS1937, BELOW S37R (THE DAMAGE IS BEYOND THE SRM 53-00-01, FIGURE 101 ALLOWABLE DAMAGE 1, DETAIL III LIMITS. TIME LIMITED REPAIR ACCOMPLISHED AS DESCRIBED IN PART 1 WORK INSTRUCTIONS, SCHEDULE REPEAT DVIS AT EVERY 5 FC (IAW PART 2), SCHEDULE HFEC INSPECTION PRIOR ; ACCUMULATION OF 5 FC (FLIGHT CYCLES) AND PERMANENT REPAIR PRIOR TO THE ACCUMULATION OF 4,000 FH (FLIGHT HOURS) AFTER PART 1, AS SCHEDULE BY MX PLANNING.)