What was found
DURING THE ACCOMPLISHMENT OF EO 4753A883, SB 747-53A2451, AD 2007-16-08. THE FWD FRAME FWD INNER CHORD AND FWD FRAME AFT INNER CHORD WAS FOUND CRACKED AT FOUR FASTENER HOLES. STRAP AND FILLERS WERE FOUND INSTALLED BETWEEN S-16L AND S-20L AND AN EXISTING SPLICE WAS FOUND INSTALLED ABOVE S-16L. CRACKS REPAIRED BY TRIMMING THE DAMAGE AND INSTALLING FILLERS, DOUBLERS AND TRIPLERS IAW MFG INSTRUCTIONS. SEE RS R53-20-37134, REV A.